SCROLL DRY VAKUM POMPALARI
Model
|
ISP-250C | ||||||||||||
Displacement L/min | 50Hz | 250 | |||||||||||
60Hz | 300 | ||||||||||||
Ultimate pressure Pa | ≦ 1.6 | ||||||||||||
Leak tightness Pa . m3/s | ≦ 1.0x10-5 | ||||||||||||
Max. inlet pressure | Atmospheric pressure | ||||||||||||
Ambient operating temperature | 5°C~40°C | ||||||||||||
Motor | Type | Single-phase induction motor 4P Totally-enclosed Insulation Class B IP44 Capacitor start TP212 Automatic Reset Type | 3-phase induction motor 4P Totally-Enclosed Insulation Class B IP44 | ||||||||||
Output | kW | 0.4 | |||||||||||
Voltage (note2) | V | 100 | 115 | 200 | 230 | 200 | 208 | 230 | 380 | 400 | 415 | 460 | |
Rated current A | 50Hz | 4.8 | - | 2.6 | 2.4 | 1.6 | - | - | 0.9 | 0.9 | 1.0 | - | |
60Hz | 4.8 | 4.3 | 2.8 | 2.4 | 1.9 | 1.9 | 1.8 | - | - | - | 1.0 | ||
Revolution min-1 {rpm} | 50Hz | 1440 | - | 1430 | 1450 | 1420 | - | - | 1440 | 1440 | 1440 | - | |
60Hz | 1710 | 1740 | 1700 | 1730 | 1660 | 1660 | 1690 | - | - | - | 1720 | ||
Noise level 1m dB(A) With air-flush ON |
≦58 ≦66 |
||||||||||||
Inlet connection | NW25 | ||||||||||||
Outlet connection | NW16 | ||||||||||||
Direction of inlet | Vertical | ||||||||||||
Dimensions mm LxWxH | 400x252x336 | 370x252x336 | |||||||||||
Mass kg | 25 | 23 | |||||||||||
Cooling system | Air-cooled | ||||||||||||
O t h e r s | With hour counter and air-flush | ||||||||||||
Note 1 : Pumping speed and ultimate pressure remain the same during air-flush operation and Standard operation. | |||||||||||||
Note 2:Motor permissible voltage is ±10%. | |||||||||||||
Note 3:Noise level is measured at ultimate pressure in an anechoic room. | |||||||||||||
Note 4 : Vapor handling is less than 25g/day (25°C, humidity 60%RH) during air-flush operation. Air-flush volume is 10L/min. | |||||||||||||
Note 5:Pump is standard operation with 200V connection specifications when it is delivered to you. | |||||||||||||
Note 6:Three phase Motor is not equipped with motor protection gear. Be sure to fit protective device. | |||||||||||||
Model
|
ISP-500C | ||||||||||||
Displacement L/min | 50Hz | 500 | |||||||||||
60Hz | 600 | ||||||||||||
Ultimate pressure Pa | ≦1 | ||||||||||||
Leak tightness Pa . m3/s | ≦1.0x10-5 | ||||||||||||
Max. inlet pressure | Atmospheric pressure | ||||||||||||
Ambient operating temperature | 5°C~40°C | ||||||||||||
Motor | Type | Single-phase induction motor 4P Totally-enclosed Insulation Class B IP44 Capacitor start TP212 Automatic Reset Type | 3-phase induction motor 4P Totally-Enclosed Insulation Class B IP44 | ||||||||||
Output | kW | 0.6 | |||||||||||
Voltage (note2) | V | 100 | 115 | 200 | 230 | 200 | 208 | 230 | 380 | 400 | 415 | 460 | |
Rated current A | 50Hz | 8.5 | - | 4.3 | 3.9 | 2.7 | - | - | 1.57 | 1.57 | 1.63 | - | |
60Hz | 10.0 | 8.6 | 4.8 | 4.0 | 2.8 | 2.6 | 2.5 | - | - | - | 1.47 | ||
Revolution min-1 {rpm} | 50Hz | 1430 | - | 1430 | 1450 | 1460 | - | - | 1470 | 1470 | 1470 | - | |
60Hz | 1660 | 1720 | 1690 | 1730 | 1740 | 1760 | 1760 | - | - | - | 1770 | ||
Noise level 1m dB(A) With air-flush ON |
≦62 ≦70 |
≦60 ≦68 |
|||||||||||
Inlet connection | NW40 | ||||||||||||
Outlet connection | NW25 | ||||||||||||
Direction of inlet | Horizontal (vertical) | ||||||||||||
Dimensions mm LxWxH | 443x328x372 (443x290x397) | 372x328x372 (372x292x397) | |||||||||||
Mass kg | 44 | 38 | |||||||||||
Cooling system | Air-cooled | ||||||||||||
O t h e r s | With hour counter and air-flush | ||||||||||||
Note 1 : Pumping speed and ultimate pressure remain the same during air-flush operation and Standard operation. | |||||||||||||
Note 2:Motor permissible voltage is ±10%. | |||||||||||||
Note 3:Noise level is measured at ultimate pressure in an anechoic room. | |||||||||||||
Note 4 : Vapor handling is less than 25g/day (25°C, humidity 60%RH) during air-flush operation. Air-flush volume is 10L/min. | |||||||||||||
Note 5:Pump is standard operation with 200V connection specifications when it is delivered to you. | |||||||||||||
Note 6:Three phase Motor is not equipped with motor protection gear. Be sure to fit protective device. |
ANEST IWATA, dünyada hava soğutmalı, yağsız, scroll tipi vakum pompalarını geliştiren ilk şirkettir. Yağsız, scroll vakum pompalarımız kompakttır ve diğer kuru vakum pompalarından daha az gürültü ve titreşim yayar. Özellikle analitik ve yarı iletkenle ilgili alanlarda temiz, yüksek kaliteli vakuma ihtiyaç duyan müşteriler tarafından çok tercih edilir.
ISP serisi vakum pompaları temiz bir vakum ortamı sunar ve hantal yağlayıcı bakımı veya sızdırmazlık suyu uygulamasının sıkıntısını ortadan kaldırır. ISP serisinde hava soğutmalı sistemi nedeniyle kurulum kısıtlamaları yoktur. ISP vakum pompaları atmosferden maksimum basınca düşük güç tüketimi sağlar.
ISS UYGULAMASI
- Püskürtme ekipmanları, Vakum biriktirme ekipmanları, İyon kaplama ekipmanları
- Hızlandırıcı, Sinkrotron Radyasyonu
- Yüzey modifikasyonu, Elektron ışını işlemi
- Gaz geri kazanım cihazları
- Vakum ekipmanları
- Kaçak detektörleri
- Cihaz taşıma sistemi
- Vakum fırını, Isıl işlem fırını
- Laboratuar kullanımı
- Vakum paketleme makinesi
KURU KAYDIRMALI VAKUM POMPASI IÇIN ÖNLEM
- Tahliye gazları
Bu pompalama sistemi sadece temiz prosesler için uygundur. Patlayıcı, yanıcı, toksik veya aşındırıcı maddeler veya kimyasallar, çözücüler veya partiküller içeren maddeler kullanmayın. ANEST IWATA, tehlikeli madde kullanan pompalarda bakım çalışmaları yapmayacaktır.
- Ortam Sıcaklığı
5 ° C ila 40 ° C arasındaki ortam çalışma sıcaklığında kullanın.